BMPRJ - 38 CLEAR FINISH SATIN, H 17

  • MSDS: BMPRJ
  • Manufacturer: PRATT AND LAMBERT
  • Product Name: 38 CLEAR FINISH SATIN, H 17
  • National Stock Number: 8010-00N025632
Product Identification

Product ID:38 CLEAR FINISH SATIN, H 17
MSDS Date:11/21/1991
FSC:8010
NIIN:00N025632
MSDS Number: BMPRJ

Responsible Party
PRATT & LAMBERT
BUFFALO, NY 14240
US

Emergency Phone: 716-873-6000; 800-255-3924

Info Phone: 716-873-6000

Cage: 77359

Contractor
PRATT & LAMBERT
BUFFALO, NY 14240 US

Telephone: 716-873-6000

Cage: 77359

Ingredients

LISTED IN ING SECTION ARE EXCEEDED USE NIOSH/MSHA

RTECS: 9999999ZZ


OSHA 29CFR1910.134 "RESP PROT", & "RESP PROTECTION A

RTECS: 9999999ZZ


EXPOS LIMITS WHICH MAY BE LISTED IN ING SECTION.

RTECS: 9999999ZZ


CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS.

RTECS: 9999999ZZ


APPRVD MECH PREFILTER MAY ALSO BE REQD.IN CONFINED

RTECS: 9999999ZZ


7.0%.

CAS: 64742-88-7

Fraction By Weight: 65%


AMORPHOUS SILICA GEL

CAS: 112926-00-8

Fraction By Weight: 5%

OSHA PEL 6 MG/M3

ACGIH TLV: 10 MG/M3 TDUST


MIGHT BE REQ FOR OVEREXPOSURE SHOULD BE DIRECTED

RTECS: 9999999ZZ


INERT ABSORB.USE ONLY NON-SPARKING TOOLS. PLACE

RTECS: 9999999ZZ


PVNT CONTAMINATION OF SEWERS, STREAMS, AND

RTECS: 9999999ZZ


CARTRIDGE RESP MAY BE REQ IN RESTRICTED VENT

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INGEST: CAN CAUSE GI IRRIT,
NAUS & VOMIT. ASPIR OF MATL INTO LUNG MAY CAUSE CHEM PNEUM WHICH
CAN BE FATAL. INHAL: MAY CAUSE NOSE/THROAT IRRIT. HIGH CONC MAY
CAUSE ACUTE CNS DEPRESS CHARACT BY H DCH, DIZZ, NAUS & CONFUSION.
EYE: MAY CAUSE IRRIT. SKIN: MAY CAUSE DEFAT & IRRIT OF SKIN.
CHRONIC: (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: REPORTS HAVE ASSOCIATED PRLNGD/RPTD
OCCUP OVEREXP TO SOLV WITH PERMANENT BRAIN AND NERVOUS SYSTEM
DAMAGE. INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING AND
INHALING CONTENTS MAY BE HARMFU L OR FATAL.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST: DO NOT INDUCE VOMIT. CALL POIS CNTRL CENTER, HOSP
EMER ROOM/PHYS IMMED. INHAL: REMOVE TO FRESH AIR IMMED. IF BRTHG
HAS STOPPED, GIVE ARTF RESP. KEEP WARM & QUIET. GET MED ATTN IMMED.
EYE: FLUS H W/LRG AMTS OF H*2O, LIFTING UPPER & LOWER LIDS
OCCASIONALLY. CONT FOR AT LEAST 15 MIN. GET MED ATTN. SKIN: REMOVE
CONTAM CLTHG. WASH AFFECTED AREA W/SOAP & H*2O. OBTAIN MED ATTN IF
IRRIT (SUPP DATA)

Fire Fighting

Flash Point Method:SCC
Flash Point:103F,39C
Lower Limits:SEE ING 1
Upper Limits:SEE ING 1
Extinguishing Media:USE NFPA CLASS B FIRE EXTING (CO*2, ALL PURPOSE DRY
CHEM/ALCOHOL FOAM) DESIGNED TO EXTING FLAM LIQ FIRES. (SUPP DATA)
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
H*2O MAY BE INEFT, BUT MAY BE USED TO COOL EXPOS CNTNRS TO PVNT
PRESS BUILD-UP & POSS AUTO-IGNIT(SUPP DATA)
Unusual Fire/Explosion Hazard:DURING EMER CNDTNS, OVEREXP TO DECOMP
PRODS MAY CAUSE HLTH HAZ. SYMP MAY NOT BE IMMED APPARENT. OBTAIN
MED ATTN. KEEP CNTNRS TIGHTLY CLSD. ISOLATE (SUPP DATA)

Accidental Release

Spill Release Procedures:KEEP SPECTATORS AWAY. ELIMINATE ALL IGNIT
SOURCES (FLAMES, HOT SURFS, & SOURCES OF ELEC, STATIC/FRICTIONAL
SPARKS). DIKE & CONTAIN SPILL W/INERT MATL (E.G. SAND, EARTH).
TRANSFER LIQ TO COVERED METAL CNTNRS FOR RECOVERY/DISP, OR REMOVE
W/ (ING 4)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 115F (46C) STORE
LARGE QUANTITIES IN COMPLIANCE WITH OSHA 29 CFR 1910.106. DO NOT
TAKE INTERNALLY. CLOSE CNTNR AFTER EACH USE.
Other Precautions:EMPTY CNTNRS MUST NOT BE WASHED & RE-USED FOR ANY
PURPOSE. CNTNRS SHD BE GROUNDED & BONDED TO RECEIVING CNTNR. DO NOT
WELD, BRAZE OR CUT ON EMPTY CNTNR. NEVER USE PRESSURE TO EMPTY.
DRUM IS NOT PRESSU RE VESSEL.

Exposure Controls

Respiratory Protection:PROPER SELECTION OF RESP PROT DEPENDS UPON MANY
FACTORS INCL DURATION/LEV OF EXPOS & CNDTNS OF USE. IN GEN EXPOS TO
ORG CHEM SUCH AS THOSE CONT IN PROD MAY NOT REQ USE OF RESP PROT IF
USED IN WELL VEN T AREAS.A NIOSH/MSHA APPRVD CHEM (ING 6)
Ventilation:PROVIDE LOC EXHST VENT IN SUFF VOL & PATTERN SO AS TO
MAINTAIN EXPOS BELOW NUISANCE DUST LIMITS & PERMISSIBLE (ING 10)
Protective Gloves:SOLVENT IMPERMEABLE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NOT LIKELY TO BE NEEDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXTING MEDIA: POLYMER FOAM IS PREFERRED FOR LRG FIRES. FIRE FIGHT PROC:
/EXPLO WHEN EXPOS TO EXTREME HEAT. IF H*2O IS USED, FOG NOZ ARE
PREFERABLE. EXPLO HAZ: FROM HEAT, ELEC EQUIP, SPARKS & FLAME. CL SD
CNTNRS MAY EXPLO WHEN EXPOS TO EXTREME HEAT. FIRST AID PROC:
PERSISTS. NOTES TO PHYS: ANY TREATMENT THAT (ING 3)

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:302F,150C
Vapor Pres:SEE ING 1
Vapor Density:HVR/AIR
Spec Gravity:0.9
Evaporation Rate & Reference:SLOWER THAN DIETHYL ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:73

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS OR ALKALINE MATERIALS.
Stability Condition to Avoid:EXCESSIVE HEAT (>115F (46C)) AND SOURCES
OF IGNITION.
Hazardous Decomposition Products:BURNING, INCLUDING WHEN HEATED BY
WELDING/CUTTING, WILL PRODUCE SMOKE, CARBON MONOXIDE AND CARBON
DIOXIDE.

Disposal

Waste Disposal Methods:DISP I/A/W FED, STATE & LOCAL LAWS. INCINERATE
ONLY IN EPA PERMITTED FACILITY. DO NOT INCINERATE CLSD CNTNRS.
OBSERVE PREC FOR DISP OF FLAM MATLS. CONTAM ABSORB MAY BE DISP IN
HAZ WASTE LANDFILL. DISP ONLY I/A/W FED, ST, & LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.